English
Language : 

V23990-P634-A-P1-19 Datasheet, PDF (3/3 Pages) Vincotech – IGBT FRED
flow 90PIM 1 600V/20A
V23990-P634-A-PM
preliminary data sheet
V23990-P634-A-02-19
Output inverter application
General conditions3 phase SPWM, Vgeon= 15 V
Vgeoff=
0V
Figure 9. Typical available electric
peak output power as a
function of heatsink temperature
Inverter
Pout=f(Th)
Rgon= 16 ȍ
Rgoff= 8 ȍ
Figure 10. Typical efficiency
as a function of output power
Inverter
efficiency=f(Pout)
7,0
100,0
6,0
99,0
2kHz
2kHz
5,0
98,0
4,0
97,0
3,0
16kHz
16kHz
96,0
2,0
1,0
95,0
0,0
60
65
70
75
80
Conditions:
Tj=125°C
DC link=
Modulation index Mi=
cosfi=
Switching freq. fsw from
parameter
in
85
90
95
Th
( o C)100
300 V
1
0,80
2 kHz to
* 2 steps
16 kHz
94,0
0,0
1,0
2,0
3,0
4,0
5,0
6,0
7,0
8,0
Pout (kW)
Conditions:
Tj=125°C
DC link= 300 V
Modulation index Mi= 1
cosfi= 0,80
Switching freq.
fsw from 2 kHz to
parameter
in * 2 steps
16 kHz
Figure 11. Typical available overload factor
as a function of motor power
and switching frequency
Inverter
Ppeak/Pnom=f(Pnom,fsw)
400
350
300
250
Conditions:
Tj=125°C
DC link= 300 V
Modulation index Mi= 1
cosfi= 0,8
Switching freq.
fsw from 1 kHz to
parameter
in * 2 steps
Heatsink temperature= 80 °C
Motor efficiency= 0,85
16 kHz
200
150 Motor nominal power (HP/kW)
100
0,75 / 0,55 1,00 / 0,74 1,50 / 1,10 2,00 / 1,47 3,00 / 2,21 5,00 / 3,68
1
969
727
484
363
242
145
2
952
714
476
357
238
143
4
918
689
459
344
230
138
8
855
641
428
321
214
128
16
744
558
372
279
186
112
coCpyoripghyt rbiygThyctobEylecVtroinniccsotech
Finsinger Feld 1, D-85521 Ottobrunnn