V23990-P628-F64-PM Datasheet, PDF (3/3 Pages) Vincotech – Output Inverter Application
flowBOOST 0
Output Inverter Application
V23990-P628-F64-PM
preliminary datasheet
900V/36A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
6
Inverter
5
"from" kHz
4
3
2
"to" kHz
1
0
60
70
80
At
Tj =
125
°C
DC link = 320
V
Mi =
1
cosfi = 1
fsw from 4 kHz to 32 kHz in steps of factor 2
90
Th ( o C)
100
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100
98
"from" kHz
96
94
92
90
88
86
"to" kHz
84
82
80
0
2
4
6
8
At
Tj =
125
°C
DC link = 320
V
Mi =
1
cosfi =
1
fsw from 4 kHz to 32 kHz in steps of factor 2
Inverter
10
12
P out (kW)
Copyright by Vincotech
3
Revision: 1