English
Language : 

V23990-K420-A50-P3-19 Datasheet, PDF (3/3 Pages) Vincotech – Output Inverter Application
MiniSKiiP® 3 PIM
Output Inverter Application
V23990-K420-A50-PM
preliminary datasheet
1200V/100A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
60
Inverter
50
2kHz
40
30
16kHz
20
10
0
60
70
80
At
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
600
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
90
Th ( o C)
100
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
500
450
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
10,00 / 7,36 15,00 / 11,03 20,00 / 14,71 25,00 / 18,39 30,00 / 22,07 40,00 / 29,42
1
574
383
287
230
191
143
2
545
363
272
218
182
136
4
490
327
245
196
163
123
8
399
266
199
159
133
0
16
273
182
136
0
0
0
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cos φ=
fsw from
Th =
0,8
1 kHz to 16kHz in steps of factor 2
80
°C
Motor eff = 0,85
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100
2kHz
99
Inverter
98
97
16kHz
96
95
94
0
20
40
At
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
600
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
60
80
Pout (kW)
copyright Vincotech
3
Revision: 3