English
Language : 

80-M006PNB006SA01-K614D Datasheet, PDF (3/3 Pages) Vincotech – Output Inverter Application
MiniSkiip 0
80-M006PNB006SA-K614C;80-M006PNB006SA01-K614D
preliminary datasheet
Output Inverter Application
600V/6A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
2,5
2kHz
2,0
16kHz
Inverter
1,5
1,0
0,5
0,0
60
65
70
75
80
85
90
95
Th
( o C)
100
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
320
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
0,50 / 0,37
1
479
2
479
4
479
8
479
16
479
0,75 / 0,55
320
320
320
320
320
1,00 / 0,74
240
240
240
240
240
1,50 / 1,10
160
160
160
160
160
2,00 / 1,47
120
120
120
120
120
3,00 / 2,21
0
0
0
0
0
Tj =
150
°C
DC link = 320
V
Mi =
1
cos φ=
fsw from
Th =
0,8
1 kHz to 16kHz in steps of factor 2
80
°C
Motor eff = 0,85
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
2kHz
99,0
98,0
97,0
96,0
16kHz
95,0
94,0
93,0
92,0
91,0
90,0
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
Inverter
4,0
4,5
Pout (kW)
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
320
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
copyright Vincotech
3
Revision: 1