English
Language : 

10-FY064PA075SG-M583F08 Datasheet, PDF (3/3 Pages) –
10-FY064PA075SG-M583F08
flowPACK 1 H
H-Bridge Application
650V/75A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
20,0
Inverter
18,0
16,0
"from" kHz
14,0
12,0
10,0
"to" kHz
8,0
6,0
4,0
2,0
0,0
60
65
70
75
80
85
90
95Th ( o C) 100
At
Tj =
150
°C
DC link = 320
V
Mi =
1
cosfi = 1
fsw from 4 kHz to 32 kHz in steps of factor 2
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
Inverter
99,5
99,0
"from" kHz
98,5
98,0
"to" kHz
97,5
97,0
96,5
0,0
5,0
10,0
15,0
At
Tj =
150
°C
DC link = 320
V
Mi =
1
cosfi = 1
fsw from 4 kHz to 32 kHz in steps of factor 2
20,0 Pout (kW) 25,0
copyright by Vincotech
3
Revision: 1