English
Language : 

V23990-P580-A46-P1-14 Datasheet, PDF (23/25 Pages) Vincotech – Motor Drives Power Generation
flowPIM 1 3rd gen
Output Inverter Application
V23990-P580-A46-PM
preliminary datasheet
1200V / 35A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
25.0
2kHz
Inverter
20.0
16kHz
15.0
10.0
5.0
0.0
60
65
70
75
80
85
90
95
Th
( o C)
100
At
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
600
V
1
0.80
2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
0,08 / 0,06
1
349
2
349
4
349
8
349
16
309
0,10 / 0,07
262
262
262
262
232
0,15 / 0,11
175
175
175
175
155
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cos φ=
fsw from
Th =
0.8
1 kHz to 16kHz in steps of factor 2
90
°C
Motor eff = 0.85
0,20 / 0,15
131
131
131
131
116
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100.0
99.0
2kHz
98.0
97.0
96.0
16kHz
95.0
94.0
93.0
92.0
91.0
90.0
0.0
5.0
10.0
15.0
20.0
25.0
At
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
600
V
1
0.80
2 kHz to 16 kHz in steps of factor 2
Inverter
30.0
35.0
Pout (kW)
copyright Vincotech
23
Revision: 1