English
Language : 

V23990-P828-F-P2-19 Datasheet, PDF (2/4 Pages) Vincotech – Typical average static loss as a function of output current
flowPACK 1 3rd gen
Output Inverter Application
V23990-P828-F-PM
preliminary datasheet
1200V/35A
Figure 5
Typical available 50Hz output current
as a function Mi*cosfi
60
50
40
30
Phase
Iout = f(Mi*cosfi)
Th = 60°C
Th = 100°C
Figure 6
Typical available 50Hz output current
as a function of switching frequency
60
50
40
Th = 100°C
30
Iout = f(fsw)
Phase
Th = 60°C
20
20
10
10
0
-1,0
-0,8
-0,6 -0,4
-0,2
0,0
0,2
0,4
0,6
0,8
1,0
Mi*cosfi
At
Tj =
150
°C
DC link = 600
V
fsw =
8
kHz
Th from 60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cosfi and switching frequency
Iout = f(fsw, Mi*cosfi)
-1,00
Iout (A)
-0,80
-0,60
44,0-48,0
40,0-44,0
36,0-40,0
32,0-36,0
28,0-32,0
24,0-28,0
20,0-24,0
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
1,00
1
2
4
8 16 32 64
fsw
At
Tj =
150
°C
DC link = 600
V
Th =
90
°C
0
1
10
At
Tj =
150
°C
DC link = 600
V
Mi*cosfi = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
60
Phase
50
40
Th = 100°C
Th = 60°C
30
20
10
0
1
10
At
Tj =
150
°C
DC link = 600
V
Th from 60 °C to 100 °C in steps of 5 °C
Mi =
0
100
fsw (kHz)
copyright by Vincotech
2
Revision: 2