V23990-P825-F-P2-19 Datasheet, PDF (2/4 Pages) Vincotech – Typical average static loss as a function of output current
flowPACK 1 3rd gen
Output Inverter Application
V23990-P825-F-PM
preliminary datasheet
600V/100A
Figure 5
Typical available 50Hz output current
as a function Mi*cosfi
140
120
Phase
Iout = f(Mi*cosfi)
Th = 60°C
100
80
Th = 100°C
60
40
20
0
-1,0
-0,8
-0,6
-0,4
-0,2
0,0
0,2
0,4
0,6
0,8
1,0
Mi*cosfi
At
Tj =
150
°C
DC link = 320
V
fsw =
16
kHz
Th from 60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cosfi and switching frequency
Iout = f(fsw, Mi*cosfi)
-1,00
Iout (A)
114,0-120,0
108,0-114,0
102,0-108,0
96,0-102,0
90,0-96,0
84,0-90,0
78,0-84,0
72,0-78,0
66,0-72,0
60,0-66,0
-0,80
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
At
Tj =
150
DC link = 320
Th =
90
1,00
1
2
4
8 16 32 64
fsw
°C
V
°C
Figure 6
Typical available 50Hz output current
as a function of switching frequency
140
120
Iout = f(fsw)
Phase
Th = 60°C
100
Th = 100°C
80
60
40
20
0
1
10
At
Tj =
150
°C
DC link = 320
V
Mi*cosfi = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
140
Phase
120
Th = 60°C
100
80
Th = 100°C
60
40
20
0
1
10
At
Tj =
150
°C
DC link = 320
V
Th from 60 °C to 100 °C in steps of 5 °C
Mi =
0
100
fsw (kHz)
copyright by Vincotech
2
Revision: 2