English
Language : 

V23990-P765-A-D2-19 Datasheet, PDF (2/3 Pages) Vincotech – flow PIM 2 3rd
flow PIM 2 3rd
V23990-P765-A-PM
datasheet
Output Inverter Application
600 V / 100 A
Figure 5
Typical available 50Hz output current
as a function Mi*cosfi
160
140
Phase
Iout = f(Mi*cosfi)
Th = 60°C
120
100
80
Th = 100°C
60
40
20
0
-1,0
-0,8 -0,6
-0,4 -0,2
0,0
0,2
0,4
0,6
0,8
1,0
Mi*cosfi
At
Tj =
150
°C
DC link = 320
V
fsw =
16
kHz
Th from 60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cosfi and switching frequency
Iout = f(fsw, Mi*cosfi)
-1,00
Iout (A)
140,0-150,0
130,0-140,0
120,0-130,0
110,0-120,0
100,0-110,0
90,0-100,0
80,0-90,0
70,0-80,0
60,0-70,0
-0,80
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
At
Tj =
150
DC link = 320
Th =
80
1,00
1
2
4
8 16 32
fsw
(kHz)
°C
V
°C
Figure 6
Typical available 50Hz output current
as a function of switching frequency
160
Iout = f(fsw)
Th = 60°C
140
Phase
120
100
80
Th = 100°C
60
40
20
0
1
10
At
Tj =
150
°C
DC link = 320
V
Mi*cosfi = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
140
Phase
120
Th = 60°C
100
80
60
Th = 100°C
40
20
0
1
10
At
Tj =
150
°C
DC link = 320
V
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
copyright Vincotech
2