English
Language : 

V23990-P760-A50-D1-19 Datasheet, PDF (2/3 Pages) Vincotech – Output Inverter Application
V23990-P760-A50
flow2
Output Inverter Application
1200V/100A
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
150
Th = 60°C
125
Th = 100°C
100
Phase
Iout = f(Mi*cos φ)
75
50
25
0
-1,0
-0,5
0,0
At
Tj =
DC link =
fsw =
Th from
150
°C
600
V
4
kHz
60 °C to 100 °C in steps of 5 °C
0,5
Mi*cos φ 1,0
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1,0
Iout (A)
-0,8
130,0-145,0
-0,6
115,0-130,0
-0,4
100,0-115,0
-0,2
85,0-100,0
0,0
70,0-85,0
0,2
55,0-70,0
0,4
40,0-55,0
0,6
25,0-40,0
0,8
10,0-25,0
1,0
1
2
4
8 16 32 64
fsw (kHz)
At
Tj =
150
°C
DC link = 600
V
Th =
80
°C
Figure 6
Typical available 50Hz output current
as a function of switching frequency
160
Iout = f(fsw)
Th = 60°C
140
Phase
120
Th = 100°C
100
80
60
40
20
0
1
10
At
Tj =
150
°C
DC link = 600
V
Mi*cos φ = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
150
Th = 60°C
Phase
125
100
Th = 100°C
75
50
25
0
1
10
At
Tj =
DC link =
Th from
Mi =
150
°C
600
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2
Revision: 1