English
Language : 

V23990-P639-A40-P1-19 Datasheet, PDF (2/3 Pages) Vincotech – Output Inverter Application
flow90PIM 1
Output Inverter Application
V23990-P639-A40
preliminary datasheet
1200V/8A
Figure 5
Phase
Typical available 50Hz output current
as a function Mi*cosφ
Iout = f(Mi*cos φ)
12
Th = 60°C
Th = 100°C
10
8
Figure 6
Typical available 50Hz output current
as a function of switching frequency
12
Iout = f(fsw)
Th = 60°C
10
Th = 100°C
8
Phase
6
6
4
4
2
2
0
-1,0
-0,5
0,0
At
Tj =
DC link =
fsw =
Th from
150
°C
600
V
4
kHz
60 °C to 100 °C in steps of 5 °C
0,5
1,0
Mi*cos φ
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1,00
Iout (A)
11,0-12,0
10,0-11,0
9,0-10,0
8,0-9,0
-0,80
-0,60
-0,40
-0,20
0,00
0,20
7,0-8,0
0,40
6,0-7,0
0,60
0,80
At
Tj =
150
DC link = 600
Th =
80
1,00
1
2
4
8 16 32 64
fsw (kHz)
°C
V
°C
0
1
10
At
Tj =
150
°C
DC link = 600
V
Mi*cos φ = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
12
Th = 60°C
Phase
10
8
6
Th = 100°C
4
2
0
1
10
At
Tj =
DC link =
Th from
Mi =
150
°C
600
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2
Revision: 1