English
Language : 

V23990-P631-A-P1-19 Datasheet, PDF (2/3 Pages) Vincotech – igbt fred
flow 90PIM 1 600V/6A
V23990-P631-A-PM
preliminary data sheet
V23990-P631-A-02-19
Output inverter application
General conditions3 phase SPWM, Vgeon= 15 V
Vgeoff=
0V
Figure 5. Typical available 50Hz output current
as a function of Mi*cosfi
Phase
Iout=f(Mi*cosfi)
Rgon= 64 ȍ
Rgoff= 32 ȍ
Figure 6.
Typical available 50Hz output current
as a function of switching frequency
Phase
Iout=f(fsw)
14
14
Th=60°C
Th=60°C
12
12
10
10
8
8
Th=100°C
6
6
Th=100°C
4
4
2
2
0
-1,0 -0,8 -0,6 -0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0
Mi*cosfi
Conditions:
Heatsink temp.
parameter
Tj=125°C
DC link=
fsw=
Th from
in
300 V
4 kHz
60 °C to
100 °C
5 °C steps
0
1
Conditions:
Heatsink temp.
parameter
10
fsw (kHz) 100
Tj=125°C
DC link=
Mi*cosfi=
Th from
in
300 V
0,8
60 °C to 100 °C
5 °C steps
Figure 7. Typical available 50Hz output current
as a function of Mi*cosfi and fsw
Phase
Iout=f(fsw,Mi*cosfi)
Figure 8.
Typical available 0Hz output current
as a function of switching frequency
Phase
Ioutpeak=f(fsw)
Iout (A)
12-13
11-12
10-11
9-10
8-9
Conditions:
-1
-0,8
-0,6
-0,4
-0,2
0
0,2
0,4
0,6
0,8
1
1 2 4 8 16 32
fsw
Tj=125°C
DC link=
Th=
300 V
80 °C
14
Th=60°C
12
10
8
6
Th=100°C
4
2
0
1
Conditions:
Heatsink temp.
parameter
10
Tj=125°C
DC link=
Th from
in
fsw (kHz) 100
300 V
60 °C to 100 °C
5 °C steps
cCopoyprigyhrt ibgyhTtycbo yEleVctirnoncicos tech
Finsinger Feld 1, D-85521 Ottobrunnn
Revision:1