flow1
Output Inverter Application
V23990-P588-*4*-PM
preliminary datasheet
1200V/15A
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
25
Phase
Iout = f(Mi*cos φ)
Th = 60°C
20
Th = 100°C
15
Figure 6
Typical available 50Hz output current
as a function of switching frequency
25
20
Iout = f(fsw)
Phase
Th = 60°C
15
Th = 100°C
10
10
5
5
0
-1,0
-0,8 -0,6
-0,4
-0,2
0,0
0,2
0,4
0,6
0,8
1,0
Mi*cos φ
At
Tj =
DC link =
fsw =
Th from
151
°C
600
V
4
kHz
60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1,00
-0,80
Iout (A)
15,0-16,0
14,0-15,0
13,0-14,0
12,0-13,0
11,0-12,0
10,0-11,0
9,0-10,0
8,0-9,0
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
At
Tj =
151
DC link = 600
Th =
80
1
2
4
°C
V
°C
8 16 32
fsw
(kHz)
1,00
64
0
1
10
At
Tj =
151
°C
DC link = 600
V
Mi*cos φ = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
25
Phase
20
Th = 60°C
15
10
5
Th = 100°C
0
1
10
At
Tj =
DC link =
Th from
Mi =
151
°C
600
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2
Revision: 2