English
Language : 

V23990-P541-X3X-D3-19 Datasheet, PDF (2/3 Pages) Vincotech – Output Inverter Application
V23990-P541-*3*-PM
flowPIM 0
Output Inverter Application
600V/6A
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
10
Phase
Iout = f(Mi*cos φ)
Th = 60°C
8
Th = 100°C
6
Figure 6
Typical available 50Hz output current
as a function of switching frequency
10
Iout = f(fsw)
Th = 60°C
8
Th = 100°C
6
Phase
4
4
2
2
0
-1,0
-0,5
0,0
At
Tj =
DC link =
fsw =
Th from
125
°C
320
V
4
kHz
60 °C to 100 °C in steps of 5 °C
0,5
1,0
Mi*cos φ
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1,00
-0,80
Iout (A)
5,0-6,0
4,0-5,0
3,0-4,0
2,0-3,0
1,0-2,0
0,0-1,0
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
At
Tj =
125
DC link = 320
Th =
80
1,00
1
2
4
8 16 32 64
fsw (kHz)
°C
V
°C
0
1
10
At
Tj =
125
°C
DC link = 320
V
Mi*cos φ = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
9
Th = 60°C
8
Th = 100°C
7
Phase
6
5
4
3
2
1
0
1
10
At
Tj =
DC link =
Th from
Mi =
125
°C
320
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2
Revision: 3