V23990-K429-A40-D3-19 Datasheet, PDF (2/3 Pages) Vincotech – Output Inverter Application
MiniSKiiP® 3 PIM
Output Inverter Application
V23990-K429-A40-PM
1200V / 75A
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
100
Phase
Iout = f(Mi*cos φ)
90
80
Th = 60°C
70
60
50
40
Th = 100°C
30
20
10
0
-1,0
-0,8
-0,6
-0,4
-0,2
0,0
0,2
0,4
0,6
0,8
1,0
Mi*cos φ
At
Tj =
DC link =
fsw =
Th from
150
°C
600
V
4
kHz
60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1,00
Iout (A)
65,0-70,0
60,0-65,0
55,0-60,0
50,0-55,0
45,0-50,0
40,0-45,0
35,0-40,0
30,0-35,0
25,0-30,0
20,0-25,0
-0,80
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
At
Tj =
150
1
2
4
°C
8 16 32
fsw
(kHz)
1,00
64
DC link = 600
V
Th =
80
°C
Figure 6
Typical available 50Hz output current
as a function of switching frequency
90
80
Phase
Iout = f(fsw)
Th = 60°C
70
60
50
Th = 100°C
40
30
20
10
0
1
10
At
Tj =
150
°C
DC link = 600
V
Mi*cos φ = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
80
Phase
70
Th = 60°C
60
50
40
Th = 100°C
30
20
10
0
1
10
At
Tj =
DC link =
Th from
Mi =
150
°C
600
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2
Revision: 3