English
Language : 

10-FY124PA080SH-L589F48 Datasheet, PDF (2/3 Pages) –
fastPACK 1 H
10-FY124PA080SH-L589F48
10-PY124PA080SH-L589F48Y
application sheet
Output Inverter Application
1200 V / 80 A
Figure 5
Phase
Typical available 50Hz output current
as a function Mi*cosfi
I out = f(Mi*cosfi)
120
Ts=60°C
100
Figure 6
Typical available 50Hz output current
as a function of switching frequency I out = f(f sw)
120
Ts=60°C
100
Phase
80
Ts=100°C
60
40
20
0
-1,0
-0,8
-0,6
-0,4 -0,2
0,0
0,2
0,4
0,6
0,8
1,0
Voutpk/Vin*cosfi
At
Tj =
125
°C
DC link = 600
V
f sw =
8
kHz
Ts from 60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current
as a function of V outpk/Vin*cosfi and switching frequency
I out=f(f sw,Mi*cosfi)
-1,0
Iout (A)
-0,8
105,0-115,0
-0,6
95,0-105,0
-0,4
85,0-95,0
-0,2
75,0-85,0
65,0-75,0
0,0
55,0-65,0
0,2
45,0-55,0
0,4
35,0-45,0
0,6
25,0-35,0
15,0-25,0
0,8
1,0
2 4 8 16 32 64
At
Tj =
125
°C
DC link = 600
V
Ts =
80
°C
fsw (kHz)
80
60
Ts=100°C
40
20
0
1
10
At
Tj =
125
°C
DC link = 600
V
Mi*cosfi = 1
Ts from 60 °C to 100 °C in steps of 5 °C
Figure 8
Typical available 0Hz output current
as a function of switching frequency
I out=f(f sw)
120
100
Ts=60°C
80
60
40
Ts=100°C
20
0
1
10
At
Tj =
125
°C
DC link = 600
V
Mi*cosfi = 0
Ts from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Phase
fsw (kHz)
100
copyright Vincotech
2
10 Oct. 2016 / Revision: 1