English
Language : 

V23990-P849-X5X-P2-19 Datasheet, PDF (1/4 Pages) Vincotech – Output Inverter Application
flowPIM0 3rd Gen
V23990-P849-A58/A59/C58/C59-PM
preliminary datasheet
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 32 Ω
Rgoff = 32 Ω
1200V/8A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
25
IGBT
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
16
FRED
14
Mi*cosfi=1
20
Mi*cosfi=-1
12
10
15
8
10
6
5
Mi*cosfi=-1
0
0
2
4
6
8
10
12
14
16
Iout (A)
At
Tj=125°C
Mi*cosfi from -1 to 1 in steps of 0,2
4
2
Mi*cosfi=1
0
0
2
4
6
8
10
12
14
16
Iout (A)
At
Tj=125°C
Mi*cosfi from -1 to 1 in steps of -0,2
Figure 3
Typical average switching loss
as a function of output current
20,0
18,0
16,0
14,0
12,0
10,0
8,0
6,0
4,0
2,0
0,0
0
2
4
6
8
At
Tj =
125
°C
DC link = 600
V
fsw from 2 kHz to 16 kHz in 2 steps
Ploss = f(Iout)
IGBT
fsw=16kHz
fsw=2kHz
10
12
14Iout (A) 16
Figure 4
Typical average switching loss
as a function of output current
8,0
7,0
6,0
5,0
4,0
3,0
2,0
1,0
0,0
0
2
4
6
8
At
Tj =
125
°C
DC link = 600
V
fsw from 2 kHz to 16 kHz in 2 steps
Ploss = f(Iout)
FRED
fsw=16kHz
fsw=2kHz
10
12
14
16
Iout (A)
copyright Vincotech
1
Revision: 2