English
Language : 

V23990-P828-F10-P2-19 Datasheet, PDF (1/4 Pages) Vincotech – flowPACK 1 3rd gen
flowPACK 1 3rd gen
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 16 Ω
Rgoff = 16 Ω
V23990-P828-F10-PM
preliminary datasheet
1200V/35A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
100
IGBT
90
Mi*cosfi = 1
80
70
60
50
40
30
20
10
0
0
10
20
30
At
Tj =
150
°C
Mi*cosfi from -1 to 1 in steps of 0,2
Mi*cosfi = -1
40
50
60
70
Iout (A)
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
70
FRED
60
Mi*cosf i= -1
50
40
30
20
10
Mi*cosfi = 1
0
0
10
20
30
40
50
60
70
Iout (A)
At
Tj =
150
°C
Mi*cosfi from -1 to 1 in steps of 0,2
Figure 3
Typical average switching loss
as a function of output current
80,0
Ploss = f(Iout)
IGBT
Figure 4
Typical average switching loss
as a function of output current
35,0
Ploss = f(Iout)
FRED
70,0
fsw = 16kHz
60,0
50,0
40,0
30,0
20,0
10,0
0,0
0
10
20
30
40
At
Tj =
150
°C
DC link = 600
V
fsw from 2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
50
60 Iout (A) 70
30,0
fsw = 16kHz
25,0
20,0
15,0
10,0
5,0
0,0
0
10
20
30
40
At
Tj =
150
°C
DC link = 600
V
fsw from 2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
50
60
70
Iout (A)
copyright by Vincotech
1
Revision: 2