English
Language : 

V23990-P765-A-P1-19 Datasheet, PDF (1/3 Pages) Vincotech – Output Inverter Application
flowPIM 2 3rd
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 4 Ω
Rgoff = 4 Ω
V23990-P765-A-PM
prel datasheet
600V/100A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
160
IGBT
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
140
FRED
140
120
100
80
60
40
20
0
0
20
40
60
80
At
Tj =
150
°C
Mi*cosfi from -1 to 1 in steps of 0,2
Mi*cosfi = 1
Mi*cosfi = -1
100
120
140
160
Iout (A)
120
100
80
60
40
20
0
0
20
40
60
80
At
Tj =
150
°C
Mi*cosfi from -1 to 1 in steps of 0,2
Mi*cosf i= -1
Mi*cosfi = 1
100
120
140
160
Iout (A)
Figure 3
Typical average switching loss
as a function of output current
60,0
Ploss = f(Iout)
IGBT
Figure 4
Typical average switching loss
as a function of output current
30,0
Ploss = f(Iout)
FRED
50,0
25,0
fsw = 16kHz
fsw = 16kHz
40,0
20,0
30,0
15,0
20,0
10,0
10,0
0,0
0
20
40
60
80
100
At
Tj =
150
°C
DC link = 320
V
fsw from 2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
120
14I0out (A) 160
5,0
0,0
0
20
40
60
80
100
At
Tj =
150
°C
DC link = 320
V
fsw from 2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
120
140
160
Iout (A)
copyright Vincotech
1
Revision: 1