English
Language : 

V23990-P723-F04-D1-19 Datasheet, PDF (1/5 Pages) Vincotech – fastPACK 0 2nd gen, 600V/ 60A
V23990-P723-F04-PM
fastPACK 0 2nd gen, 600V/ 60A
Output inverter application
Phase shifted ZVS,
Vgeon=
15 V Vgeoff=0V
Rgon= 4 ohms
final datasheet
V23990-P723-F04-01-19
Rgoff= 2 ohms
Figure 1. Typical static loss of shifted switch
as a function of output current
IGBT
Ploss=f(Iout)
Figure 2. Typical static loss of shifted switch
as a function of output current
FRED
Ploss=f(Iout)
120
60
100
50
80
Phaseshift=1
60
40
Phaseshift=0
30
40
20
20
Phaseshift=0,1
0
0
10
20
30
40
50
60
70
Conditions:
Tj=125°C
Phaseshift
parameter Phaseshift from 0,10 to
1,00
in 0,10 steps
10
Phaseshift=0,9
0
0
10
20
30
40
50
60
70
Conditions:
Tj=125°C
Phaseshift
parameter Phaseshift from 0,00 to
0,90
in 0,10 steps
Figure 3. Typical switching loss
as a function of output current
IGBT
Ploss=f(Iout)
100,0
90,0
80,0
70,0
80kHz
60,0
50,0
40,0
30,0
20,0
10,0
0,0
0
10kHz
10
20
30
40
50
60Iout (A) 70
Conditions:
Tj=125C
Ioutpk/Iout= 1,3 DC link=
Phaseshift= 1
Switching freq.
fsw from
parameter
in
300 V
10 kHz to
* 2 steps
80 kHz
Figure 4. Typical available output current
as a function of switching frequency
Phase
Iout=f(fsw)
60
50
Th=60°C
40
30
20
10
Th=100°C
0
10
100
1000
fsw (kHz)
Conditions:
Ioutpk/Iout=
Phaseshift=
Heatsink temp.
parameter
Tj=125C
1,3 DC link=
1
Th from
in
300 V
60 °C to 100 °C
5 °C steps
Copyright by Vincotech
1
Revision: 1