English
Language : 

V23990-P63X-A-U-P1-48 Datasheet, PDF (1/3 Pages) Vincotech – selection guide
flow 90PIM 1 selection guide
V23990-P63X-A-PM
preliminary data sheet
V23990-P63X-A-02-19
Output inverter selection quide
General conditions: 3 phase SPWM, Vgeon= 15 V Vgeoff=0V
Figure 1. Typical available electric
peak output power as a
function of heatsink temperature
Inverter
Pout=f(Th)
Figure 2. Typical available electric
peak output power as a
function of switching frequency
Inverter
Pout=f(fsw)
10,0
9,0
8,0
7,0
6,0
P635
5,0
4,0
3,0
2,0
P631
1,0
0,0
60
65
70
75
80
85
90
95
Th
(
o
100
C)
Conditions:
Tj=125C
DC link=
Modulation index Mi=
cosfi=
Switching frequency fsw=
300 V
1
0,80
4 kHz
8,0
7,0
6,0
5,0
P635
4,0
3,0
2,0
P631
1,0
0,0
1
10
fsw (kHz) 100
Conditions:
Tj=125C
DC link= 300 V
Modulation index Mi= 1
cosfi= 0,80
Th= 80 °C
Pout (kW)
1,5-2,0
4,0-4,5
2,0-2,5
4,5-5,0
2,5-3,0
3,0-3,5
3,5-4,0
P635-
P634-
P633-
P632-
P631-
60
65
70
75
80
85
90
95
100
Th ( o C)
Pout (kW)
1,5-2,0
3,5-4,0
2,0-2,5
4,0-4,5
2,5-3,0
4,5-5,0
3,0-3,5
P635-
P634-
P633-
P632-
P631-
1
2
4
8
16 32
fsw (kHz)
Module type P631-
P632-
P633-
P634-
P635-
Rgon=
64 ohms
32
16
16
8
Rgoff=
32 ohms
16
8
8
4
Ccooppyryigrhitgbhy Tt ybcoyEVleicntrocnoictsech
Finsinger Feld 1, D-85521 Ottobrunnn
Revision:1