V23990-P586-*2*-PM
flow1
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 16 Ω
Rgoff = 16 Ω
600V/50A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
120
IGBT
100
Mi*cosfi = 1
80
60
40
20
Mi*cosfi = -1
0
0
10
20
30
40
50
60
70
80
Iout (A)
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
90
FWD
80
Mi*cosf i= -1
70
60
50
40
30
20
10
Mi*cosfi = 1
0
0
10
20
30
40
50
60
70
80
Iout (A)
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 3
Typical average switching loss
as a function of output current
40,0
Ploss = f(Iout)
IGBT
Figure 4
Typical average switching loss
as a function of output current
7,0
Ploss = f(Iout)
FWD
35,0
fsw = 16kHz
30,0
25,0
20,0
15,0
10,0
5,0
0,0
0
fsw = 2kHz
10
20
30
40
50
60
At
Tj =
DC link =
fsw from
125
°C
320
V
2 kHz to 16 kHz in steps of factor 2
70Iout (A) 80
6,0
fsw = 16kHz
5,0
4,0
3,0
2,0
1,0
0,0
0
fsw = 2kHz
10
20
30
40
50
60
At
Tj =
DC link =
fsw from
125
°C
320
V
2 kHz to 16 kHz in steps of factor 2
70
80
Iout (A)
copyright Vincotech