English
Language : 

V23990-P585-X2X-D2-19 Datasheet, PDF (1/3 Pages) Vincotech – Output Inverter Application
V23990-P585-*2*-PM
flow1
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 16 Ω
Rgoff = 16 Ω
600V/30A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
60
IGBT
50
Mi*cosfi = 1
40
30
20
10
Mi*cosfi = -1
0
0
5
10
15
20
25
30
35
40
45
50
Iout (A)
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
45
FWD
40
35
Mi*cosf i= -1
30
25
20
15
10
5
Mi*cosfi = 1
0
0
5
10
15
20
25
30
35
40
45
50
Iout (A)
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 3
Typical average switching loss
as a function of output current
18,0
Ploss = f(Iout)
IGBT
16,0
fsw = 16kHz
14,0
12,0
10,0
8,0
6,0
4,0
2,0
0,0
0
fsw = 2kHz
5
10
15
20
25
30
35
40
At
Tj =
DC link =
fsw from
125
°C
320
V
2 kHz to 16 kHz in steps of factor 2
I4o5ut (A) 50
Figure 4
Typical average switching loss
as a function of output current
5,0
Ploss = f(Iout)
FWD
4,5
fsw = 16kHz
4,0
3,5
3,0
2,5
2,0
1,5
1,0
0,5
0,0
0
fsw = 2kHz
5
10
15
20
25
30
35
40
At
Tj =
DC link =
fsw from
125
°C
320
V
2 kHz to 16 kHz in steps of factor 2
45
50
Iout (A)
copyright Vincotech
1