English
Language : 

V23990-P546-X2X-D3-19 Datasheet, PDF (1/3 Pages) Vincotech – Output Inverter Application
V23990-P546-*2*-PM
flowPIM 0
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = 0 V
Rgon = 8 Ω
Rgoff = 4 Ω
600V/30A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
60
Mi*cosfi = 1
50
IGBT
40
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
40
Mi*cosf i= -1
FWD
30
30
20
20
10
0
0
10
20
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 3
Typical average switching loss
as a function of output current
20
15
10
Mi*cosfi = -1
30
40
I out (A) 50
Ploss = f(Iout)
IGBT
fsw = 16kHz
0
0
10
20
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 4
Typical average switching loss
as a function of output current
6
5
4
Mi*cosfi = 1
30
40 I out (A)
50
Ploss = f(Iout)
FWD
fsw = 16kHz
10
3
5
fsw = 2kHz
0
0
10
20
30
40
At
Tj =
DC link =
fsw from
125
°C
320
V
2 kHz to 16 kHz in steps of factor 2
I out (A) 50
2
1
fsw = 2kHz
0
0
10
20
30
40
At
Tj =
DC link =
fsw from
125
°C
320
V
2 kHz to 16 kHz in steps of factor 2
50
I out (A)
copyright Vincotech
1
Revision: 3