English
Language : 

V23990-K429-A50-P3-19 Datasheet, PDF (1/3 Pages) Vincotech – Output Inverter Application
V23990-K429-A50-PM
preliminary datasheet
MiniSKiiP® 3 PIM
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 8 Ω
Rgoff = 8 Ω
1200V/75A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
200
Mi*cosfi = 1
IGBT
150
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
125
Mi*cosf i= -1
100
FWD
75
100
50
50
25
0
0
25
50
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 3
Typical average switching loss
as a function of output current
180
150
Mi*cosfi = -1
75
100
I out (A) 125
IGBT
Ploss = f(Iout)
fsw = 16kHz
0
0
25
50
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 4
Typical average switching loss
as a function of output current
60
50
Mi*cosfi = 1
75
100
125
I out (A)
FWD
Ploss = f(Iout)
fsw = 16kHz
120
40
90
30
60
20
30
0
0
25
50
75
At
Tj =
DC link =
fsw from
150
°C
600
V
2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
100
125
I out (A)
10
0
0
25
50
75
At
Tj =
DC link =
fsw from
150
°C
600
V
2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
100
125
I out (A)
copyright Vincotech
1
Revision: 3