V23990-K220-A40-P1-19 Datasheet, PDF (1/3 Pages) Vincotech – Output Inverter Application
MiniSKiiP® 2 PIM
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 16 Ω
Rgoff = 16 Ω
V23990-K220-A40-PM
preliminary datasheet
1200V / 35A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
100
IGBT
90
Mi*cosfi = 1
80
70
60
50
40
30
20
10
0
0
10
20
30
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0.2
Mi*cosfi = -1
40
50
60
70
Iout (A)
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
90
FRED
80
Mi*cosf i= -1
70
60
50
40
30
20
10
Mi*cosfi = 1
0
0
10
20
30
40
50
60
70
Iout (A)
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0.2
Figure 3
Typical average switching loss
as a function of output current
100.0
Ploss = f(Iout)
IGBT
90.0
80.0
fsw = 16kHz
70.0
60.0
50.0
40.0
30.0
20.0
10.0
0.0
0
10
20
30
40
At
Tj =
DC link =
fsw from
150
°C
600
V
2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
50
60 Iout (A) 70
Figure 4
Typical average switching loss
as a function of output current
25.0
20.0
Ploss = f(Iout)
FRED
fsw = 16kHz
15.0
10.0
5.0
0.0
0
10
20
30
40
At
Tj =
DC link =
fsw from
150
°C
600
V
2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
50
60
70
Iout (A)
copyright Vincotech
1
Revision: 1