V23990-K200-A40-D3-19 Datasheet, PDF (1/3 Pages) Vincotech – Output Inverter Application
V23990-K200-A40-PM
MiniSKiiP® 1 PIM
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 32 Ω
Rgoff = 32 Ω
1200V / 15A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
60
IGBT
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
60
FRED
Mi*cosfi = 1
50
50
Mi*cosf i= -1
40
40
30
30
20
20
10
0
0
5
10
15
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Mi*cosfi = -1
20
25
30
35
Iout (A)
Figure 3
Typical average switching loss
as a function of output current
45,0
Ploss = f(Iout)
IGBT
40,0
fsw = 16kHz
35,0
30,0
25,0
20,0
15,0
10,0
5,0
0,0
0
5
10
15
20
At
Tj =
DC link =
fsw from
150
°C
600
V
2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
25
30 Iout (A) 35
10
0
0
5
10
15
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 4
Typical average switching loss
as a function of output current
14,0
Mi*cosfi = 1
20
25
30
35
Iout (A)
Ploss = f(Iout)
FRED
12,0
fsw = 16kHz
10,0
8,0
6,0
4,0
2,0
0,0
0
5
10
15
20
At
Tj =
DC link =
fsw from
150
°C
600
V
2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
25
30
35
Iout (A)
copyright Vincotech
1
Revision: 3