English
Language : 

10-XZ122PB100SH-M819F28 Datasheet, PDF (1/3 Pages) –
flow PHASE 0
10-FZ122PB100SH-M819F28
10-PZ122PB100SH-M819F28Y
application sheet
Output Inverter Application
1200 V / 100 A
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 1 Ω
Rgoff = 1 Ω
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
250
IGBT
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
250
FWD
Mi*cosfi = 1
200
200
Mi*cosf i= -1
150
150
100
100
50
0
0
20
40
60
80
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Mi*cosfi = -1
100
120
140
160
Iout (A)
Figure 3
Typical average switching loss
as a function of output current
180
160
IGBT
Ploss = f(Iout)
fsw = 16kHz
140
120
100
80
60
40
20
0
0
fsw = 2kHz
20
40
60
80
100
120
140
160
Iout (A)
At
Tj =
150
°C
DC link = 600
V
fsw from 2 kHz to 16 kHz in steps of factor 2
50
0
0
20
40
60
80
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Mi*cosfi = 1
100
120
140
160
Iout (A)
Figure 4
Typical average switching loss
as a function of output current
70
FWD
Ploss = f(Iout)
60
fsw = 16kHz
50
40
30
20
10
fsw = 2kHz
0
0
20
40
60
80
100
120
At
Tj =
150
°C
DC link = 600
V
fsw from 2 kHz to 16 kHz in steps of factor 2
140
160
Iout (A)
copyright Vincotech
1
12 Okt. 2016 / Revision 1