English
Language : 

SP2402 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – Thermoelectric Cooler
marlow industries, inc. 
Subsidiary of II-VI INCORPORATED
TECHNICAL DATA SHEET
SP2402
Thermoelectric Cooler
RoHS EU Compliant
TYPICAL PERFORMANCE VALUES
Hot Side Temperature (°C)
∆ Tmax (°C-dry N2):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
27°C
109
8.7
5.3
8.9
1.54
MECHANICAL CHARACTERISTICS
.855
[21.72]
.339
[8.61]
.511
[12.98]
1.113
[28.27]
Positive Lead
Leads: 22 AWG (0.64) Bus
Solid Tinned Copper
Negative Lead
2.00 +/-.25
[50.80+/-6.35]
50°C
123
9.5
5.3
9.9
--
.265+/-.015
[6.73 +/-0.38]
Cold Side
Ceramic Material: Alumina and Beryllia (AB)
Millimeters are in [ ]
.009 [0.23] A
.001 [0.03]
.003 [0.08]
A
Beryllium Oxide Handling
Precautions
Beryllium oxide can be toxic only when
dust, mist, or fumes containing particles
small enough to enter the lungs are
inhaled. For the user, precautions required
are to avoid grinding, machining or
pulverizing the material by mechanical,
thermal, or chemical processing.
marlow industries, inc.R
ORDERING OPTIONS
Model Number
SP2402-01AB
SP2402-02AB
SP2402-03AB
SP2402-04AB
Description
both surfaces are metallized
hot side exterior is metallized
no metallization
metallized. top and base
DOC # 102-0230 REV J - PAGE 1 OF 2
AVAILABLE MODIFICATIONS
Pretinned metallized ceramic surface(s) with 117°C solder.
Thermistor mounted on edge of cold side ceramic. (Calibration
available.)
Elevated temperature burn-in with test data provided.
-04AB: Special height and parallelism requirements and lead
orientation.