PRIMARY CONTROL - PC PIN
Module Enable/Disable
The module may be disabled by pulling PC to 0 V (2.3 V
max) with respect to the –Input. This may be done with an
open collector transistor, relay, or optocoupler. Converters
may be disabled with a single transistor or relay either directly
or via “OR’ing” diodes for 2 or more converters. See Figure 2.
Primary Auxiliary Supply
During normal operation only, the PC Pin can source 5.7 V @
1.5 mA. In the example shown in Figure 4, PC powers a mod-
ule enabled LED.
150 V Input
Module Alarm
The module contains “watchdog” circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will
shut down and PC will go low. PC will periodically go high
and the module will check to see if the fault (as an example,
Input Undervoltage) has cleared. If the fault has not been
cleared, PC will go low again and the cycle will restart. The
SC pin will go low in the event of a fault and return to its nor-
mal state after the fault has been cleared. See Figures 3 and 5.
+In
PC
Disable
PR
–In
Disable = PC <2.3V
Figure 2 — Module enable/disable.
+Out
+S
SC
–S
–Out
+IN
PC
PR
–IN
SW1
Auto
Restart
1M
2-20 ms typ.
f (VIN)
SW1, 2, & 3
shown in
"Fault" position
5.7 Vdc
(0-3 mA)
Input Undervoltage
Input Overvoltage (See Note 1)
Overtemperature
Module Faults
50 Ω
SW2
SW3 1 K
1.23
Vdc
6K
1 Not applicable for 300 Vdc input family
+OUT
+S
SC
–S
– OUT
Figure 3 — PC/SC module alarm logic.
"Module
4kΩ
Enabled"
+In
+Out
PC
+S
SC
PR
–S
–In
–Out
Figure 4 — LED on-state indicator.
Optocoupler
4 kΩ
+In
+Out
PC
+S
SC
PR
–S
–In
–Out
Figure 6 — Isolated on-state indicator.
150 V Mini Family
Page 9 of 13
Rev 2.7
09/2015
Fault
PC 5.7 V
SC 1.23 V
40 μs typ.
2–20 ms typ.
Figure 5 — PC/SC module alarm timing.
+In
+Out
PC
+S
SC
PR
–S
–In
–Out
1.00V
Alarm
Figure 7 — Secondary side on-state indicator.
vicorpower.com
800 927.9474