English
Language : 

DCM3623X36G17C2YZZ Datasheet, PDF (9/25 Pages) Vicor Corporation – Isolated, Regulated DC Converter
DCM3623x36G17C2yzz
High Level Functional State Diagram
Conditions that cause state transitions are shown along arrows. Sub-sequence activities listed inside the state bubbles.
Application of
VIN
VIN > VIN-INIT
INITIALIZATION
SEQUENCE
tINIT delay
Powertrain: Stopped
FT = True
VIN > VIN-UVLO+ and
not Over-temp
TR mode latched
STANDBY
Powertrain: Stopped
FT = True
EN = True and
No Faults
tON delay
EN = False
tOFF delay
EN = False
tOFF-MIN delay
EN = False
tMIN-OFF delay
NON LATCHED
FAULT
tOFF
RFeamuIlnotpvueIntdpOuVt LUOVLoOr
Powertrain: Stopped
FT = True
InpuItnOpuVtLUOVoLrO
SOFT START
VOUT Ramp Up
tss delay
Powertrain: Active
FT = False
tSS Expiry
RUNNING
Regulates VOUT
Output OVP
Powertrain: Active
FT = False
Output OVP
REINITIALIZATION
SEQUENCE
tINIT delay
Powertrain: Stopped
FT = True
Fault Removed
NON LATCHED
FAULT
tFAULT
Powertrain: Stopped
FT = True
EN = False
LATCHED
FAULT
Powertrain: Stopped
FT = True
DCM™ DC-DC Converter
Page 9 of 25
Rev 1.1
04/2017
vicorpower.com
800 927.9474