English
Language : 

BCM352X125Y300A00 Datasheet, PDF (9/21 Pages) Vicor Corporation – Isolated Fixed Ratio DC-DC Converter
BCM352x125y300A00
Application Characteristics
The following values, typical of an application environment, are collected at TCASE = 25ºC unless otherwise noted. See associated figures for general trend data.
12
10
8
6
4
2
0
330 335 340 345 350 355 360 365
Input Voltage (V)
-40ºC
25ºC
100ºC
Figure 2 — No load power dissipation vs. Vin
96.0
95.5
95.0
94.5
94.0
93.5
93.0
-40
-20
0
20
40
60
Case Temperature (°C)
80
100
VIN:
330V
352V
365V
Figure 3 — Full load efficiency vs. temperature; Vin
98
94
90
86
82
78
74
70
66
62
0
5
10
15
20
25
30
Output Load (A)
VIN:
330V
352V
365V
Figure 4 — Efficiency at TCASE = -40°C
21
19
17
15
13
11
9
7
0
5
10
15
20
25
30
Output Load (A)
VIN:
330V
352V
365V
Figure 5 — Power dissipation at TCASE = -40°C
98
96
94
92
90
88
86
84
82
80
78
0
5
VIN:
10
15
20
25
30
Output Load (A)
330V
352V
365V
Figure 6 — Efficiency at TCASE = 25°C
BCM® Bus Converter
Page 9 of 21
Rev 2.0
08/2016
19
17
15
13
11
9
7
5
0
5
VIN:
10
15
20
25
30
Output Load (A)
330V
352V
365V
Figure 7 — Power dissipation at TCASE = 25°C
vicorpower.com
800 927.9474