English
Language : 

BCD384F120T300A00 Datasheet, PDF (9/21 Pages) Vicor Corporation – BCM® Bus Converter
BCM384x120y300Azz
Application Characteristics
The following values, typical of an application environment, are collected at TCASE = 25ºC unless otherwise noted. See associated figures for general trend data.
12
11
10
9
8
7
6
5
4
360
365 370
TCASE:
375 380 385
Input Voltage (V)
-40ºC
25ºC
390 395 400
100ºC
Figure 3 — No load power dissipation vs. Vin
96.0
95.5
95.0
-40
-20
0
20
40
60
Case Temperature (ºC)
80
100
VIN:
360V
384V
400V
Figure 4 — Full load efficiency vs. temperature; Vin
97
94
91
88
85
82
79
76
73
0
3
6
VIN:
9 12 15 18 21 24 27
Load Current (A)
360V
384V
400V
Figure 5 — Efficiency at TCASE = -40°C
27
24
21
18
15
12
9
6
3
0
3
6
VIN:
9 12 15 18 21 24 27
Load Current (A)
360V
384V
400V
Figure 6 — Power dissipation at TCASE = -40°C
97
94
91
88
85
82
79
76
73
0
3
6
VIN:
9 12 15 18 21 24 27
Load Current (A)
360V
384V
400V
Figure 7 — Efficiency at TCASE = 25°C
27
24
21
18
15
12
9
6
3
0
3
6
VIN:
9 12 15 18 21 24 27
Load Current (A)
360V
384V
400V
Figure 8 — Power dissipation at TCASE = 25°C
BCM® Bus Converter
Page 9 of 21
Rev 1.5
08/2016
vicorpower.com
800 927.9474