English
Language : 

BCM384X120Y1K5ACZ Datasheet, PDF (8/25 Pages) Vicor Corporation – Fixed Ratio DC-DC Converter
BCM384x120y1K5ACz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL
≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Protection SECONDARY to PRIMARY (Reverse Direction)
Secondary Overvoltage Lockout
Threshold
VSEC_OVLO+ Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
13.1
13.6
14.1
V
Secondary Overvoltage Lockout
Response Time
tPRI_OVLO
100
µs
Secondary Undervoltage Lockout
Threshold
VSEC_UVLO- Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
3.4
3.75
4.1
V
Secondary Undervoltage Lockout
Response Time
tSEC_UVLO
100
µs
Primary Undervoltage Lockout
Threshold
Applies only to reversilbe products in forward and in
VPRI_UVLO-_R reverse direction; IPRI_DC ≤ 20 while VPRI_UVLO-_R
110
120
130
V
< VPRI_DC < VPRI_MIN
Primary Undervoltage Recovery
Threshold
VPRI_UVLO+_R
Applies only to reversilbe products in forward and in
reverse direction;
120
130
150
V
Primary Undervoltage Lockout
Hysteresis
VPRI_UVLO_HYST_R
Applies only to reversilbe products in forward and in
reverse direction;
10
V
Primary Output Overcurrent Trip
Threshold
IPRI_OUT_OCP Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
4.2
5.3
6.6
A
Primary Output Overcurrent
Response Time Constant
tPRI_OUT_OCP Effective internal RC filter
3
ms
Primary Short Circuit Protection Trip
Threshold
IPRI_SCP
Module latched shutdown with VPRI_DC < VPRI_UVLO-_R
5.8
A
Primary Short Circuit Protection
Response Time
tPRI_SCP
1
µs
BCM® Bus Converter
Page 8 of 25
Rev 1.5
07/2015
vicorpower.com
800 927.9474