English
Language : 

D048C010T010M2N Datasheet, PDF (6/14 Pages) Vicor Corporation – DC-DC Converters Quarter Brick, 48 Vin Family
Specifications, continued
PRELIMINARY
SAFETY SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Isolation voltage
Input to output
2,250
Vdc
Isolation resistance
10
MΩ
Agency approvals (pending)
cTÜVus
CE Mark
Notes
Complies with basic insulation requirements
Input to output
UL/CSA 60950, EN 60950
Low voltage directive
THERMAL SPECIFICATIONS
Parameter
Min
Operating case temperature
-40
Storage temperature
-40
Temperature limiting
125
Thermal capacity
Pin soldering temperature
Wave
Hand
Typ
Max
Unit
100
°C
+150
°C
130
135
°C
22.8
Ws/°C
500 (260)
750 (390)
°F (°C)
°F (°C)
Notes
Measured at output side of VTM
Junction temperature, PRM or VTM
<5 sec
<7 sec
GENERAL SPECIFICATIONS
Parameter
MTBF
MIL-HDBK-217F
Weight
Dimensions
Min
Typ
Max
1,500
3.7 (104)
2.28 x 1.45 x 0.27
57,9 x 36,8 x 6,8
Unit
khrs
oz (g)
in
mm
Notes
25°C, GB
LxWxH
LxWxH
CONTROL SPECIFICATIONS – ON/OFF PIN
Parameter
Min
Typ
Max
Unit
Disable voltage (P version)
– 0.6
1.7
Vdc
Enable voltage (P version)
2.8
6.2
Vdc
Enable voltage (M version)
– 0.6
0.7
Vdc
Disable voltage (M version)
1.8
6.2
Vdc
Notes
Referenced to –in
Referenced to –in
Referenced to –in
Referenced to –in