Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL
≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
General Powetrain PRIMARY to SECONDARY Specification (Forward Direction) Cont.
Effective Primary Capacitance
(Internal)
Effective Secondary Capacitance
(Internal)
Effective Secondary Output
Capacitance (External)
Effective Secondary Output
Capacitance (External)
CPRI_INT
Effective Value at 400 VPRI_DC
CSEC_INT
Effective Value at 50 VSEC_DC
CSEC_OUT_EXT
CSEC_OUT_AEXT
Excessive capacitance may drive module into SC
protection
CSEC_OUT_AEXT Max = N * 0.5 * CSEC_OUT_EXT MAX, where
N = the number of units in parallel
0.37
µF
25.6
µF
100
µF
Protection PRIMARY to SECONDARY (Forward Direction)
Auto Restart Time
Primary Overvoltage Lockout
Threshold
Primary Overvoltage Recovery
Threshold
Primary Overvoltage Lockout
Hysteresis
Primary Overvoltage Lockout
Response Time
Primary Undervoltage Lockout
Threshold
Primary Undervoltage Recovery
Threshold
Primary Undervoltage Lockout
Hysteresis
Primary Undervoltage Lockout
Response Time
Startup into a persistent fault condition. Non-Latching
tAUTO_RESTART fault detection given VPRI_DC > VPRI_UVLO+
292.5
357.5
ms
VPRI_OVLO+
420
436
450
V
VPRI_OVLO-
405
426
440
V
VPRI_OVLO_HYST
10
V
tPRI_OVLO
100
µs
VPRI_UVLO-
200
226
250
V
VPRI_UVLO+
225
244
259
V
VPRI_UVLO_HYST
15
V
tPRI_UVLO
100
µs
From VPRI_DC = VPRI_UVLO+ to powertrain active, EN
Primary Undervoltage Startup Delay tPRI_UVLO+_DELAY floating, (i.e One time Startup delay form application
20
ms
of VPRI_DC to VSEC_DC)
From powertrain active. Fast Current limit protection
Primary Soft-Start Time
tPRI_SOFT-START disabled during Soft-Start
1
ms
Secondary Output Overcurrent Trip
Threshold
ISEC_OUT_OCP
37.5
47
59
A
Secondary Output Overcurrent
Response Time Constant
tSEC_OUT_OCP Effective internal RC filter
3.6
ms
Secondary Output Short Circuit
Protection Trip Threshold
ISEC_OUT_SCP
52
A
Secondary Output Short Circuit
Protection Response Time
tSEC_OUT_SCP
1
µs
Overtemperature Shutdown
Threshold
tOTP+
Temperature sensor located inside controller IC
125
°C
Overtemperature Recovery
Threshold
tOTP–
105
110
115
°C
Undertemperature Shutdown
Threshold
Temperature sensor located inside controller IC;
tUTP
Protection not available for M-Grade units.
-45
°C
Startup into a persistent fault condition. Non-Latching
Undertemperature Restart Time
tUTP_RESTART
fault detection given VPRI_DC > VPRI_UVLO+
3