SPECIFICATIONS (CONT.)
General Specifications
Parameter
MTBF
MIL-HDBK-217F
Isolation specifications
Voltage
Capacitance
Resistance
Agency approvals
Mechanical
Weight
Dimensions
Length
Width
Height
Thermal
Over temperature shutdown
Thermal capacity
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Baseplate to sink; flat greased surface
Baseplate to sink; thermal pad
Auxiliary Pins
Parameter
Primary control (PC)
DC voltage
Module disable voltage
Module enable voltage
Current limit
Enable delay time
Disable delay time
Min
Typ
Max
Unit
3.5
Mhrs
2,250
Vdc
3,000
pF
10
MΩ
cTÜVus
CE Mark
RoHS
1.10/31,3
oz /g
1.91/ 48,6
1.09/ 27,7
0.37/ 9,5
in / mm
in / mm
in / mm
125
130
135
°C
23.8
Ws /°C
7.7
°C / W
2.9
°C / W
0.40
°C / W
0.36
°C / W
Notes
25°C, GB
Input to output
Input to output
Input to output
UL /CSA 60950-1, EN 60950-1
Low voltage directive
See Mechanical Drawings, Figure 18, 19
Baseplate model
Baseplate model
Baseplate model
Junction temperature
Min
Typ
Max
Unit
4.8
5.0
5.2
Vdc
2.4
2.5
Vdc
2.5
2.6
Vdc
2.4
2.5
2.9
mA
255
ms
40
µs
Notes
Source only
See Figure 12, time from PC low to output low
Figure 12 — VOUT at full load vs. PC disable
Bus Converter Module
BC048A030T021FP
Figure 13 — PC signal during fault
vicorpower.com