English
Language : 

B048X480Y30A Datasheet, PDF (6/18 Pages) Vicor Corporation – Unregulated DC-DC Converter
Not Recommended for New Designs
B048x480y30A
5.0 APPLICATION CHARACTERISTICS
The following values, typical of an application environment, are collected at TC = 25ºC unless otherwise noted. See associated figures
for general trend data.
No Load Power Dissipation vs. Line
8
Full Load Efficiency vs. TCASE
98
7
6
5
96
4
3
2
1
38 40 42 44 46 47 49 51 53 55
Input Voltage (V)
-40°C
25°C
100°C
94
-40
-20
0
20
40
60
Case Temperature (°C)
80
100
VIN :
38 V
48 V
55 V
Figure 2 — No load power dissipation vs. VIN
Figure 3 — Full load efficiency vs. temperature; VIN
Efficiency & Power Dissipation -40°C Case
98
27
96
24
94
21
92
18
90
15
88
12
86
9
84
PD
6
82
3
80
0
0
1
2
3
4
5
6
7
Load Current (A)
VIN:
38 V
48 V
55 V
38 V
48 V
55 V
Figure 4 — Efficiency and power dissipation at TC = -40°C
Efficiency & Power Dissipation 25°C Case
98
27
96
24
94
21
92
18
90
15
88
12
86
9
84
6
82
PD
3
80
0
0
1
2
3
4
5
6
7
Load Current (A)
VIN:
38 V
48 V
55 V
38 V
48 V
55 V
Figure 5 — Efficiency and power dissipation at TC = 25°C
Efficiency & Power Dissipation 100°C Case
98
27
96
24
94
21
92
18
90
15
88
12
86
9
84
6
82
PD 3
80
0
0
1
2
3
4
5
6
7
Load Current (A)
VIN:
38 V
48 V
55 V
38 V
48 V
55 V
Figure 6 — Efficiency and power dissipation at TC = 100°C
ROUT vs. TCASE at VIN = 48 V
300
260
220
180
140
100
-40
-20
0
20
40
60
Case Temperature (°C)
Full Load
Figure 7 — ROUT vs. temperature
80
100
BCM® Bus Converter
Page 6 of 18
Rev 1.1
04/2014
vicorpower.com
800 927.9474