English
Language : 

B048X160Y24A Datasheet, PDF (6/18 Pages) Vicor Corporation – Unregulated DC-DC Converter
Not Recommended for New Designs
B048x160y24A
5.0 APPLICATION CHARACTERISTICS
The following values, typical of an application environment, are collected at TC = 25ºC unless otherwise noted. See associated figures
for general trend data.
No Load Power Dissipation vs. Line
9
8
7
6
5
4
3
2
1
38 40 42 44 46 47 49 51 53 55
Input Voltage (V)
-40°C
25°C
100°C
Full Load Efficiency vs. TCASE
96
96
95
95
94
-40
-20
0
20
40
60
80
100
Case Temperature (°C)
VIN :
38 V
48 V
55 V
Figure 2 — No load power dissipation vs. VIN
Figure 3 — Full load efficiency vs. temperature; VIN
Efficiency & Power Dissipation -40°C Case
97
27
94
24
91
21
88
18
85
15
82
12
79
9
76
6
73
PD
3
70
0
0
2
4
6
8
10 12 14 16
Load Current (A)
VIN:
38 V
48 V
55 V
38 V
48 V
55 V
Figure 4 — Efficiency and power dissipation at TC = -40°C
Efficiency & Power Dissipation 25°C Case
97
27
94
24
91
21
88
18
85
15
82
12
79
9
76
6
73
PD
3
70
0
0
2
4
6
8
10 12 14 16
Load Current (A)
VIN:
38 V
48 V
55 V
38 V
48 V
55 V
Figure 5 — Efficiency and power dissipation at TC = 25°C
Efficiency & Power Dissipation 100°C Case
97
27
94
24
91
21
88
18
85
15
82
12
79
9
76
6
73
PD
3
70
0
0
2
4
6
8
10 12 14
16
Load Current (A)
VIN:
38 V
48 V
55 V
38 V
48 V
55 V
Figure 6 — Efficiency and power dissipation at TC = 100°C
ROUT vs. TCASE at VIN = 48 V
40
36
32
28
24
20
-40
-20
0
20
40
60
Case Temperature (°C)
Full Load
80
100
Figure 7 — ROUT vs. temperature
BCM® Bus Converter
Page 6 of 18
Rev 1.0
01/2014
vicorpower.com
800 927.9474