English
Language : 

AIM1714XB6MC7D5YZZ Datasheet, PDF (6/14 Pages) Vicor Corporation – Chassis Mount or PCB Mount Form Factor
AIM1714xB6MC7D5yzz
Electrical Specifications
Specifications apply over all line and load conditions, 50 Hz and 60 Hz line frequencies, TJ = 25°C, unless otherwise noted.
Boldface specifications apply over the temperature range of the specified product grade.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max Unit
Input voltage range,
continuous operation
VIN
Input voltage range,
transient, non-operational (peak),
VIN
30s minimum interval
Input Specification
Source line frequency range
fline
Power factor*
PF
See note below
Output Specification
Output power
POUT
Output Current (continuous)
IOUT
* Please see PFM in VIA package datasheet for power factor
85
264
VRMS
600
V
47
63
Hz
-
450
W
5.3
A
AIM™ in a VIA Package
Page 6 of 14
Rev 1.1
07/2016
vicorpower.com