English
Language : 

VTM48EX020Y080B00 Datasheet, PDF (5/18 Pages) Vicor Corporation – High Efficiency, Sine Amplitude Converter
VTM48E x 020 y 080 B00
5.0 APPLICATION CHARACTERISTICS
The following values, typical of an application environment, are collected at TC = 25ºC unless otherwise noted. See associated figures
for general trend data.
ATTRIBUTE
No load power dissipation
Efficiency (ambient)
Efficiency (hot)
Output resistance (cold)
Output resistance (ambient)
Output resistance (hot)
Output voltage ripple
VOUT transient (positive)
VOUT transient (negative)
SYMBOL
PNL
hAMB
hHOT
ROUT_COLD
ROUT_AMB
ROUT_HOT
VOUT_PP
VOUT_TRAN+
VOUT_TRAN-
CONDITIONS / NOTES
VIN = 48 V, PC enabled
VIN = 48 V, IOUT = 80 A
VIN = 48 V, IOUT = 80 A, TC = 100ºC
VIN = 48 V, IOUT = 80 A, TC = -40ºC
VIN = 48 V, IOUT = 80 A
VIN = 48 V, IOUT = 80 A, TC = 100ºC
COUT = 0 F, IOUT = 80 A, VIN = 48 V,
20 MHz BW, Section 12
IOUT_STEP = 0 A TO 80A, VIN = 48 V,
ISLEW = 19 A /us
IOUT_STEP = 80 A to 0 A, VIN = 48 V
ISLEW = 59 A /us
TYP
UNIT
4.4
W
92.1
%
91.7
%
0.8
mΩ
1.1
mΩ
1.4
mΩ
156
mV
30
mV
110
mV
No Load Power Dissipation vs. Line
11
9
7
5
3
1
26 29 32 35 38 41 43 46 49 52 55
TCASE:
Input Voltage (V)
-40°C
25°C
Figure 1 — No load power dissipation vs. VIN
100°C
Full Load Efficiency vs. Case Temperature
94
92
90
88
86
-40
-20
0
20
40
60
80
100
Case Temperature (°C)
VIN :
26 V
48 V
55 V
Figure 2 — Full load efficiency vs. temperature
Efficiency & Power Dissipation -40°C Case
96
45
92
40
88
η
35
84
30
80
25
76
20
72
PD
15
68
10
64
5
60
0
0
8 16 24 32 40 48 56 64 72 80
Load Current (A)
VIN:
26 V
48 V
55 V
26 V
48 V
55 V
Figure 3 — Efficiency and power dissipation at –40°C
Efficiency & Power Dissipation 25°C Case
96
28
92
24
88
η
20
84
16
80
12
76
PD
8
72
4
68
0
0
8 16 24 32 40 48 56 64 72 80
Load Current (A)
VIN:
26 V
48 V
55 V
26 V
48 V
55 V
Figure 4 — Efficiency and power dissipation at 25°C
VTM® Current Multiplier
Page 5 of 18
Rev 1.0
5/2013
vicorpower.com
800 735.6200