English
Language : 

V048X080Y030A Datasheet, PDF (5/18 Pages) Vicor Corporation – High Efficiency, Sine Amplitude Converter
Not Recommended for New Designs
V048x080y030A
5.0 APPLICATION CHARACTERISTICS
The following values, typical of an application environment, are collected at TC = 25ºC unless otherwise noted. See associated figures
for general trend data.
ATTRIBUTE
No load power dissipation
Efficiency (ambient)
Efficiency (hot)
Output resistance (cold)
Output resistance (ambient)
Output resistance (hot)
Output voltage ripple
VOUT transient (positive)
VOUT transient (negative)
SYMBOL
PNL
hAMB
hHOT
ROUT_COLD
ROUT_AMB
ROUT_HOT
VOUT_PP
VOUT_TRAN+
VOUT_TRAN-
CONDITIONS / NOTES
VIN = 48 V, PC enabled
VIN = 48 V, IOUT = 30 A
VIN = 48 V, IOUT = 30 A, TC = 100ºC
VIN = 48 V, IOUT = 30 A, TC = -40ºC
VIN = 48 V, IOUT = 30 A
VIN = 48 V, IOUT = 30 A, TC = 100ºC
COUT = 0 F, IOUT = 30 A, VIN = 48 V,
20 MHz BW, Section 12
IOUT_STEP = 0 A TO 30 A, VIN = 48 V,
ISLEW = 19 A /us
IOUT_STEP = 30 A to 0 A, VIN = 48 V
ISLEW = 85 A /us
TYP
UNIT
4.3
W
95.7
%
95.6
%
5.8
mΩ
7.1
mΩ
8.3
mΩ
225
mV
145
mV
130
mV
11
10
9
8
7
6
5
4
3
2
1
26
No Load Power Dissipation vs. Line
29 32 35 38 41 43 46 49 52 55
Input Voltage (V)
TCASE:
-40°C
25°C
Figure 1 — No load power dissipation vs. VIN
100°C
Full Load Efficiency vs. TCASE
98
96
94
92
-40
-20
0
20
40
60
Case Temperature (C)
80 100
VIN :
26 V
48 V
55 V
Figure 2 — Full load efficiency vs. temperature
Efficiency & Power Dissipation -40°C Case
96
30
92
25
88
84
20
80
15
76
72
PD
10
68
5
64
60
0
0
5
10
15
20
25
30
Load Current (A)
VIN:
26 V
48 V
55 V
26 V
48 V
55 V
Figure 3 — Efficiency and power dissipation at –40°C
Efficiency & Power Dissipation 25°C Case
96
24
92
20
88
16
84
12
80
PD
8
76
4
72
0
0
5
10
15
20
25
30
Load Current (A)
VIN:
26 V
48 V
55 V
26 V
48 V
55 V
Figure 4 — Efficiency and power dissipation at 25°C
VTM® Current Multiplier
Page 5 of 18
Rev 1.1
02/2015
vicorpower.com
800 927.9474