FE175D480C033FP-00 Datasheet, PDF (5/20 Pages) Vicor Corporation – Complete AC-DC PCB-mounted solution | |||
|
◁ |
FE175D480C033FP-00
Signal Characteristics
Specifications apply over all line and load conditions, 50 Hz and 60 Hz line frequencies, TC = 25 °C, unless otherwise noted.
Boldface specifications apply over the temperature range of the specified Product Grade.
ENABLE : EN
⢠The EN pin enables and disables the VI BRICK® AC Front End; when held below 0.8 V the unit will be disabled.
⢠The EN pin can reset the VI BRICK AC Front End after a latching OVP event.
⢠The EN pin voltage is 3.3 V during normal operation.
⢠The EN pin is referenced to the âIN pin of the module.
Signal Type
Digital Input
State
Attribute
Symbol Conditions / Notes
Min
Typ
Max Unit
Startup EN enable threshold VEN_EN
2.00
V
EN disable time
TEN_DIS From any point in line cycle
9
16
ms
Standby
EN disable threshold
EN resistance to
disable
VEN_DIS
REN_EXT
Max allowable resistance to
-IN required to disable the module
0.80
V
14
kΩ
RESERVED : RSV1, RSV3
No connections should be made to these pins
-IN
⢠Warning: -IN and N are not at the same potential and must not be connected together.
⢠The -IN pin is the signal reference ground for the EN pin
⢠The -IN pin also serves as an access point for the common mode bypass filter to comply with EN55022 Class B for Conducted Emissions.
VI BRICK® AC Front End
Page 5 of 20
Rev 1.1
11/2012
vicorpower.com
800 735.6200
|
▷ |