CONTROL FUNCTIONS - PC PIN
Module Enable/Disable
The module may be disabled by pulling PC below 2.3V with
respect to the âInput. This may be done with an open collector
transistor, relay, or optocoupler. Multiple converters may be
disabled with a single transistor or relay either directly or via
âORâingâ diodes. See Figure 1.
Primary Auxiliary Supply
At 5.7V, PC can source up to 1.5mA. In the example shown in
Figure 3, PC powers a module enabled LED.
Module Alarm
The module contains âwatchdogâ circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will shut
down and PC will go low. PC will periodically go high and the
module will check to see if the fault (as an example,
overtemperature) has cleared. If the fault has not been cleared,
PC will go low again and the cycle will restart. The SC pin will
go low in the event of a fault and return to its normal state after
the fault has been cleared. See Figures 2 and 4.
+In
PC
PR
Disable
âIn
Disable = PC <2.3V
Figure 1âModule enable/disable.
+In
PC
"Module
4kâ¦
Enabled"
PR
âIn
Figure 3âLED on-state indicator.
+In
PC
PR
âIn
SW1
Auto
Restart
2-20ms typ.
f(VIN)
Input Undervoltage
Input Overvoltage
Over Temperature
Module Faults
50â¦
SW2
1K
SW3
5.7Vdc
(0-3mA)
SW1, 2, & 3 shown
in "Fault" position
6K
1.23
Vdc
+Out
SC
âOut
Figure 2âPC/SC module alarm logic.
Fault
PC 5.7V
SC 1.23V
40µs typ.
2-20ms typ.
Figure 4âPC/SC module alarm timing.
Optocoupler
+In
PC
4kâ¦
PR
âIn
+Out
SC
âOut
1.00V
Alarm
Figure 5âIsolated on-state indicator.
Figure 6âSecondary side on-state indicator.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
48V Micro Family
Set your site on VICOR at www.vicorpower.com
Rev. 5.3
Page 4 of 8
|
▷ |