English
Language : 

V300A8E400BL Datasheet, PDF (4/13 Pages) Vicor Corporation – DC-DC Converter Module
MODULE SPECIFIC OPERATING SPECIFICATIONS
2 Vout, 160 W (e.g. V300A2C160BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
Typ
72.5
74
80
2.7
2.8
7.9
±0.02
0
81.6
92
56
92
3.3 Vout, 264 W (e.g. V300A3V3C264BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
Typ
79
81
80
4.14
4.3
8.1
±0.02
0
81.6
92
56
92
3.3 Vout, 200 W (e.g. V300A3V3C200BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
Typ
78.1
79.6
80
4.14
4.3
6.2
±0.02
0
61.8
69.7
42.4
69.7
5 Vout, 400 W (e.g. V300A5C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
Typ
81.5
83
100
6.03
6.25
6.2
±0.02
0
81.6
92
56
92
5 Vout, 300 W (e.g. V300A5C300BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
Typ
83.2
84.2
150
6.03
6.25
8.5
±0.02
0
61.2
69
42
69
Max
Unit
%
100
mV
2.9
Volts
8.1
Watts
±0.2
%
80
Amps
112
Amps
112
Amps
Max
Unit
%
100
mV
4.46
Volts
9.4
Watts
±0.2
%
80
Amps
112
Amps
112
Amps
Max
Unit
%
100
mV
4.46
Volts
12
Watts
±0.2
%
60.6
Amps
81.9
Amps
81.9
Amps
Max
Unit
%
125
mV
6.47
Volts
9.3
Watts
±0.2
%
80
Amps
112
Amps
112
Amps
Max
Unit
%
188
mV
6.47
Volts
9.2
Watts
±0.2
%
60
Amps
81
Amps
81
Amps
300 V Input
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwidth
25°C; recycle input voltage or PC to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
300 V Maxi Family
Page 4 of 13
Rev 9.2
07/2014
vicorpower.com
800 927.9474