English
Language : 

V110A24C400BL_16 Datasheet, PDF (4/14 Pages) Vicor Corporation – DC-DC Converter Module
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3VOUT, 200W (e.g. S110A3V3C200BL, V110A3V3C200BL)
Parameter
Min
Typ
Max
Efficiency
S110A3V3C200BL (enhanced efficiency) 82.3 86.5
V110A3V3C200BL (standard efficiency) 81.0 82.0
Ripple and noise
90
113
Output OVP setpoint
4.14
4.3
4.46
Dissipation, standby
6.1
8.2
Load regulation
±0.02
±0.2
Load current
0
60.6
Current limit
61.8
69.7
81.9
Short circuit current
42.4
69.7
81.9
Unit
Notes
%
Nominal input; full load; 25°C
mV
p-p; Nominal input; full load; 20MHz bandwidth
Volts
25°C; recycle input voltage or PC to restart (>100ms off)
Watts
No load
%
No load to full load; nominal input
Amps
Amps
Output voltage 95% of nominal
Amps
Output voltage <250mV
3.3VOUT, 150W (e.g. S110A3V3C150BL, V110A3V3C150BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S110A3V3C150BL (enhanced efficiency) 82.0 86.0
%
Nominal input; full load; 25°C
V110A3V3C150BL (standard efficiency) 80.5
81.8
Ripple and noise
85
107
mV
p-p; Nominal input; full load; 20MHz bandwidth
Output OVP setpoint
4.14
4.3
4.46
Volts
25°C; recycle input voltage or PC to restart (>100ms off)
Dissipation, standby
6.1
7
Watts
No load
Load regulation
±0.02
±0.2
%
No load to full load; nominal input
Load current
0
45.45
Amps
Current limit
46.4
52.3
61.5
Amps
Output voltage 95% of nominal
Short circuit current
31.8
52.3
61.5
Amps
Output voltage <250mV
5VOUT, 300W (e.g. S110A5C300BL, V110A5C300BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S110A5C300BL (enhanced efficiency) 85.2 88.1
%
Nominal input; full load; 25°C
V110A5C300BL (standard efficiency) 83.0
84.9
Ripple and noise
80
100
mV
p-p; Nominal input; full load; 20MHz bandwidth
Output OVP setpoint
6.03
6.25
6.47
Volts
25°C; recycle input voltage or PC to restart (>100ms off)
Dissipation, standby
12.1
13.1
Watts
No load
Load regulation
±0.02
±0.2
%
No load to full load; nominal input
Load current
0
60
Amps
Current limit
61.2
69
81
Amps
Output voltage 95% of nominal
Short circuit current
42
69
81
Amps
Output voltage <250mV
5VOUT, 200W (e.g. S110A5C200BL, V110A5C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S110A5C200BL (enhanced efficiency) 86.3 88.5
%
Nominal input; full load; 25°C
V110A5C200BL (standard efficiency) 84.5
85.5
Ripple and noise
166
208
mV
p-p; Nominal input; full load; 20MHz bandwidth
Output OVP setpoint
6.03
6.25
6.47
Volts
25°C; recycle input voltage or PC to restart (>100ms off)
Dissipation, standby
8.3
9.7
Watts
No load
Load regulation
±0.02
±0.2
%
No load to full load; nominal input
Load current
0
40
Amps
Current limit
40.8
46
54
Amps
Output voltage 95% of nominal
Short circuit current
28
46
54
Amps
Output voltage <250mV
110V Maxi Family
Page 4 of 14
Rev 3.0
06/2016
vicorpower.com
800 927.9474