English
Language : 

IB054E096T40N1-00 Datasheet, PDF (4/13 Pages) Vicor Corporation – 5:1 Intermediate Bus Converter Module: Up to 300 W Output
IB054E096T40N1-00
SPECIFICATIONS (CONT.)
Control & Interface Specifications
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Enable (negative logic)*
Module enable threshold
Module enable current
Module disable threshold
Module disable current
Disable hysteresis
Enable pin open circuit voltage
EN to –IN resistance
Enable (positive logic)*
Module enable threshold
Module disable threshold
EN source current (operating)
EN voltage (operating)
*See part numbering on page 11
Referenced to –IN
0.8
VEN = 0.8 V
VEN = 2.4 V
Open circuit, 10 V applied between EN and -IN
Referenced to –IN
2.0
VEN = 5 V
4.7
IPC-9592A, Based on Class II Category 2 the following detail is applicable. – Pre-conditioning required
Environmental Qualification
Test Description
5.2.3 HALT (Highly Accelerated Life testing)
Test Detail
Low Temp
High Temp
Rapid Thermal Cycling
6 DOF Random Vibration Test
Input Voltage Test
Output Load Test
Combined Stresses Test
Vdc
130
200
µA
2.4
Vdc
10
µA
500
mV
2.5
3.0
Vdc
35
kΩ
2.5
3.0
Vdc
1.45
Vdc
2
mA
5
5.3
Vdc
Quantity Tested
3
3
3
3
3
3
3
5.2.4 THB (Temp. Humidity Bias)
(72 hr presoak required) 1000 hrs – Continuous Bias
30
Power cycle - On 42 minutes
5.2.5 HTOB (High Temp. Operating Bias)
Off 1 minute, On 1 minute, Off 1 minute, On 1 minute, Off 1 minute,
30
On 1 minute, Off 1 minute, On 1 minute, Off 10 minutes. Alternating
between maximum and minimum operating Voltage every hour.
5.2.6 TC (Temp. Cycling)
700 cycles , 30 minute dwell at each extreme – 20C minimum ramp rate.
30
5.2.7 Power Cycling
Reference IPC-9592A
3
5.2.8 – 5.2.13 Shock and Vibration
Random Vibration – Operating IEC 60068-2-64 (normal operation vibration)
3
Random Vibration Non-operating (transportation) IEC 60068-2-64
3
Shock Operating - normal operation shock IEC 60068-2-27
3
Free fall - IEC 60068-2-32
3
Drop Test 1 full shipping container (box)
12
5.2.14.1 Corrosion Resistance – Not required
N/A
5.2.14.2 Dust Resistance – Unpotted class II GR-1274-CORE
3
5.2.14 Other Environmental Tests
5.2.14.3 SMT Attachment Reliability IPC-9701 - J-STD-002
3
5.2.14.4 Through Hole solderability – J-STD-002
5
ESD Classification Testing
Sample size assumes CDM testing
12
Total Quantity
161
IBC MODULE
Page 4 of 13
Rev 1.1
10/2012
vicorpower.com
800 735.6200