English
Language : 

DCM24AP050X180A50 Datasheet, PDF (4/25 Pages) Vicor Corporation – Isolated, Regulated DC Converter
DCM24AP050x180A50
Part Ordering Information
Device
DCM
DCM = DCM
Input Voltage Range
Package Type
Output
Voltage x 10
Temperature Grade Output Power Revision
24A
P
50
x
180
A5
24A = 18/24/36 V
P = ChiP TH
50 = 5.0 V
T = -40 to 125°C
M = -55 to 125°C
180 = 180 W
A5
Version
0
Analog Control
Interface Version
Absolute Maximum Ratings
The absolute maximum ratings below are stress ratings only. Operation at or beyond these maximum ratings can cause permanent damage to the device.
Electrical specifications do not apply when operating beyond rated operating conditions.
Parameter
Input Voltage (+IN to –IN)
Input Voltage Slew Rate
TR to - IN
EN to -IN
FT to -IN
Output Voltage (+Out to –Out)
Dielectric withstand (input to output)
Internal Operating Temperature
Storage Temperature
Average Output Current
Basic insulation
T Grade
M Grade
T Grade
M Grade
Comments
Min
-0.5
-1
-0.3
-0.3
-0.3
-0.5
2250
-40
-55
-40
-65
Max
65.0
1
3.5
3.5
3.5
5
7.2
125
125
125
125
50.0
Unit
V
V/µs
V
V
V
mA
V
Vdc
°C
°C
°C
°C
A
Figure 1 — Thermal Specified Operating Area: Max Output Power
Figure 2 — Electrical Specified Operating Area
vs. Case Temp, Single unit at minimum full load efficiency
DCM™ DC-DC Converter
Page 4 of 25
Rev 1.1
07/2015
vicorpower.com
800 927.9474