English
Language : 

B048X080Y24A Datasheet, PDF (4/18 Pages) Vicor Corporation – Unregulated DC-DC Converter
Not Recommended for New Designs
B048x080y24A
3.0 SIGNAL CHARACTERISTICS
Specifications apply over all line and load conditions unless otherwise noted; Boldface specifications apply over the temperature
range of -40°C < TC < 125°C (T-Grade); All other specifications are at TC = 25°C unless otherwise noted.
PRIMARY CONTROL : PC
• The PC pin enables and disables the BCM. When held low,
the BCM is disabled.
• In an array of BCM modules, PC pins should be interconnected
to synchronize start up and permit start up into full load conditions.
• PC pin outputs 5 V during normal operation. PC pin internal bias
level drops to 2.5 V during fault mode, provided VIN remains
in the valid range.
SIGNAL TYPE
ANALOG
OUTPUT
STATE
Regular
Operation
Standby
Transition
Start Up
Start Up
Regular
Operation
ATTRIBUTE
PC voltage
PC available current
PC source (current)
PC resistance (internal)
PC capacitance (internal)
PC load resistance
PC time to start
PC enable threshold
SYMBOL
CONDITIONS / NOTES
VPC
IPC_OP
IPC_EN
RPC_INT
CPC_INT
RPC_S
TON1
Internal pull down resistor
Section 7
To permit regular operation
VPC_EN
MIN TYP MAX UNIT
4.7 5.0 5.3 V
2.0 3.5 5.0 mA
50 100
µA
50 150 400 kΩ
1000 pF
60
kΩ
330 450 630 ms
2.0 2.5 3.0 V
DIGITAL
INPUT / OUPUT
Standby
Transition
PC disable duration
TPC_DIS_T Minimum time before attempting re-enable 1
s
PC threshold hysteresis
VPC_HYSTER
50
mV
PC enable to VOUT time
TON2 VIN = 48 V for at least TON1 ms
50 100 150 µs
PC disable to standby time
TPC-DIS
4 10 µs
PC fault response time
TFR_PC From fault to PC = 2 V
100
µs
TEMPERATURE MONITOR : TM
• The TM pin monitors the internal temperature of the controller IC
within an accuracy of ±5°C.
• Can be used as a "Power Good" flag to verify that
the BCM module is operating.
• Is used to drive the internal comparator for Overtemperature Shutdown.
SIGNAL TYPE
STATE
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
MIN TYP MAX UNIT
ANALOG
OUTPUT
DIGITAL
OUTPUT
(FAULT FLAG)
Regular
Operation
Transition
Standby
TM voltage range
TM voltage reference
TM available current
TM gain
TM voltage ripple
TM capacitance (external)
TM fault response time
TM voltage
TM pull down (internal)
VTM
VTM_AMB
ITM
ATM
VTM_PP
CTM_EXT
TFR_TM
VTM_DIS
RTM_INT
TJ controller = 27°C
CTM = 0 pF, VIN = 48 V, IOUT = 30 A
From fault to TM = 1.5 V
Internal pull down resistor
2.12
4.04 V
2.95 3.00 3.05 V
100
µA
10
mV/°C
120 200 mV
50 pF
10
µs
0
V
25 40 50 kΩ
RESERVED : RSV
Reserved for factory use. No connection should be made to this pin.
BCM® Bus Converter
Page 4 of 18
Rev 1.1
08/2014
vicorpower.com
800 927.9474