B048K096T24 Datasheet, PDF (4/15 Pages) Vicor Corporation – VI ChipTM - BCM Bus Converter Module | |||
|
◁ |
Specifications (continued)
PRELIMINARY
Vâ¢I Chip Bus Converter Module
Figure 7â Output voltage ripple at full load and 48 Vin; without any
external bypass capacitor.
Ripple vs. Output Power
180
160
140
120
100
80
60
40
20
0
0
20 40 60 80 100 120 140 160 180 200 220 240
Output Power (W)
Figure 9â Output voltage ripple vs. output power at 48 Vin line without
any external bypass capacitor.
Figure 8âOutput voltage ripple at full load and 48 Vin with 10 µF ceramic
external bypass capacitor and 20 nH of distribution inductance.
Figure 10â 0 -25.0 A load step with 47 µF input capacitor and no
output capacitor.
Figure 11â 25.0- 0 A load step with 47 µF input capacitance.
vicorpower.com 800-735-6200
Vâ¢I Chip Bus Converter Module
B048K096T24
Rev. 3.0
Page 4 of 15
|
▷ |